Our double-axis trackers are based on tried-and-true reliable design allowing for various adjustments and operational flexibility. The construction has been engineered to require minimum maintenance and operates fully automatically. The construction is projected as a separate entity carrying 16 (tracker type D16) or 30 monocrystalline Phono Solar panels for the D30 tracker. The main reason for the implementation of double-axis tracking systems is the possible increase of up to 30% of energy generated by the system with the investment increase required being only 50% compared to the fixed constructions. The construction is made of corrosion resistant steel and its motion is secured by two electric motors governed by central logic unit. According to the information obtained from solar sensors this unit coordinates panel surface tracking in accordance with the motion of the Sun. The logic unit is supplied by the ordinary network system with a voltage of 230V. Tracker engines usually operate only for 30-45 minutes a day. Their energy consumption is only 30-45 Wh. The tracker durability exceeds 25 years.
| Sensor type (tracker) |
Double-axis tracker (3.2kw) |
Double-axis tracker (6.9kw) |
||||
|---|---|---|---|---|---|---|
| Model | D 16 | D 30 | ||||
| Top power output | up to 3.9 kWp | up to 7.2 kWp | ||||
| Panel surface | 23m2 | 49m2 | ||||
| Maximum load | 500kg | 800kg | ||||
| Appliance weight | 600kg | 1,100kg | ||||
| Azimut | Propulsion type | worm drive (roller bearings) | worm drive (roller bearings) | |||
| Horizontal motion range | By 240° | By 240° | ||||
| Engine | 3,000rpm (120w / dc24v) (ratio 68,526 : 1 ® 0.043 rpm) |
3,000rpm (120w / dc24v) (ratio 62,694 : 1 ® 0.047 rpm) |
||||
| Angle | Propulsion type | linear propulsion | linear propulsion | |||
| Vertical motion range | By 70° | By 70° | ||||
| Engine | 3,000rpm (120w / dc24v) (ratio 288 : 1 ® 10.4 rpm) |
3,000rpm (120w / dc24v) (ratio 288 : 1 ® 10.4 rpm) |
||||
| Self-consumption | 250w (max. 75wh/day) | 250w (max. 60wh/day) | ||||
| Construction material | Corrosion resistant steel | |||||
| Sun monitoring method | closed-lopp (real-time based solar sensor) | |||||
| Sensor type | sensor with photodiodes | |||||
| Monitoring accuracy | ± 1° for ordinary pv sensors / ± 0.1° for CPV (concentrator) sensors. | |||||
| Minimum monitoring luminosity | 3,000 Lux | |||||
| Logic unit | 10 buttons: (automatic/manual mode), (motion east/west/south/ ínorth), (number insertion by means of two keys / esc / enter) |
|||||
| Facultative accessories | monitoring system, outdoor temperature sensor, wind velocity sensor, angle sensor,… | |||||
| Max. wind velocity | Regular operation | 14m/s (50km/h) | ||||
| Safe mode (angle 0°) |
35m/s (126km/h) | |||||
| Constant angle45° | 25m/s (90km/h) | |||||
| Safe mode | the appliance is turned into horizontal position automatically if:
1) luminosity keeps below 3,000 Lux for over two hours 2) sensors display excess values |
|||||
Tracking construction photogallery
Would you like to know more about the tracker concrete base construction (anchored) procedure? You can find more information in our Magazine.
A fixed/tracking system power output comparison
![]()
Would you like to know more about the tracker concrete base construction (anchored) procedure? You can find more information in our Magazine.